Your Cart

Your cart is empty

Browse products and add items to your cart

HomeProductsAnesthesia & RespiratoryAnesthesia MachinesABBOTT Lifecare 5000 IV infusion pump
ABBOTT Lifecare 5000 IV infusion pump
Click to zoom
GOOD

Product Details

BrandABBOTT
CategoryAnesthesia Machines
ConditionGOOD
Year2026
Posted22 Jun 2026
Views1
ABBOTT LifeCare 5000 Infusion pump Good condition Tested-functional FEATURES: The Abbott Lifecare 5000 Plum Infusion System is a multilane, general purpose, volumetric infusion system designed to meet the need for hospital-wide device standardization. By means of internal switch-settings, a qualified bio-technician can configure the LifeCare 5000 System to best suit the clinical needs and census changes of the hospital. The Unit is designed for accurate, non-pulsatile administration of single fluid regimens, dual-channel regimens, piggybacks, and multidose regimens over a wide range of delivery rates and fluid viscosities. It can administer a variety of medical fluids, from 5% Dextrose Injection, USP, to enteral feeding products and blood. Primary and secondary doses of compatible drugs can be delivered concurrently. DELIVERY RATE RANGE: - Micro Mode: 0.1 to 99.0 mL/hr (in 0.1 mL increments). The total of the primary rate plus the secondary rate cannot exceed 99.9 mL/hr in Micro Mode. Note: while using the concurrent delivery feature in the Micro Mode, neither the primary rate nor the secondary rate can be less than 0.5 mL/hr. - Macro Mode: 1 to 999 mL/hr (in 1 mL increments. The total of the primary rate plus the secondary rate cannot exceed 700 mL) in 1 mL/hr in Macro Mode. DOSE LIMIT RANGE: - Micro Mode: 0.1 to 999 mL (in 0.1 mL increments). - Macro Mode: 1 to 9999 mL (in 1 mL increments). Operating Back Pressure: 02 to 10 psig. The maximum pressure is user-selectable from 1 to 10 psig, via the front panel touchswitches. Secondary Doses: For dual-channel delivery, a single dose of a secondary fluid may be administered. For multidose delivery, 1 to 24 doses of a secondary fluid may be administered at intervals from 15 minutes to 24 hours. OCCLUSION ALARM: Distal: The distal occlusion alarm sounds within two pumping cycles after the distal set tubing or set outlet fitting becomes occluded. Proximal: The proximal occlusion alarm sounds within five pumping cycles if the tubing proximal to the cassette becomes occluded. Air-in-Alarm: The stopped air in distal line alarm will sound if a bubble 100 uL or larger passes the distal air-in-line sensors. Alarm may actually sound at detection of a bubble as small as 50 uL) Proximal: The stopped air in proximal line alarm will sound if approximately 1200 uL or more passes trough the proximal air-in-line sensors.

Technical Specifications

ConditionUsed - Good
CountryFrance
Warranty (month)1
AvailabilityIn stock
Insulin infusionYes
SyringeYes
AmbulatoryYes
PCAYes
ModelLifecare 5000
BrandABBOTT
CategoryIV infusion pumps

Questions & Answers

Ask a Question

Questions are reviewed by our team before being published.

ABBOTT Lifecare 5000 IV infusion pump

GOODYear 20261 ViewsBasic
3 people viewing this right now
€67.00

Get the best price — instantly

Verified sellers Avg. response 2 hrs

By submitting, you agree to our terms. Response typically within 2 hours.

Typically responds in 2 hours
Inspection report available
Worldwide shipping available
Locked

Seller information hidden

Unlock to reveal name, rating & contact

Seller contact is locked

Unlock seller phone, email and full profile for a one-time fee.

Safety Tips

  • Inspect equipment before payment
  • Use MellMed secure payment
  • Verify equipment serial numbers
  • Check CE/FDA compliance docs

Your Cart

Your cart is empty

Browse products and add items to your cart

ABBOTT Lifecare 5000 IV infusion pump | MellMed