
Click to zoom
GOOD
Product Details
| Brand | ABBOTT |
| Category | Anesthesia Machines |
| Condition | GOOD |
| Year | 2026 |
| Posted | 22 Jun 2026 |
| Views | 1 |
ABBOTT LifeCare 5000 Infusion pump Good condition Tested-functional FEATURES: The Abbott Lifecare 5000 Plum Infusion System is a multilane, general purpose, volumetric infusion system designed to meet the need for hospital-wide device standardization. By means of internal switch-settings, a qualified bio-technician can configure the LifeCare 5000 System to best suit the clinical needs and census changes of the hospital. The Unit is designed for accurate, non-pulsatile administration of single fluid regimens, dual-channel regimens, piggybacks, and multidose regimens over a wide range of delivery rates and fluid viscosities. It can administer a variety of medical fluids, from 5% Dextrose Injection, USP, to enteral feeding products and blood. Primary and secondary doses of compatible drugs can be delivered concurrently. DELIVERY RATE RANGE: - Micro Mode: 0.1 to 99.0 mL/hr (in 0.1 mL increments). The total of the primary rate plus the secondary rate cannot exceed 99.9 mL/hr in Micro Mode. Note: while using the concurrent delivery feature in the Micro Mode, neither the primary rate nor the secondary rate can be less than 0.5 mL/hr. - Macro Mode: 1 to 999 mL/hr (in 1 mL increments. The total of the primary rate plus the secondary rate cannot exceed 700 mL) in 1 mL/hr in Macro Mode. DOSE LIMIT RANGE: - Micro Mode: 0.1 to 999 mL (in 0.1 mL increments). - Macro Mode: 1 to 9999 mL (in 1 mL increments). Operating Back Pressure: 02 to 10 psig. The maximum pressure is user-selectable from 1 to 10 psig, via the front panel touchswitches. Secondary Doses: For dual-channel delivery, a single dose of a secondary fluid may be administered. For multidose delivery, 1 to 24 doses of a secondary fluid may be administered at intervals from 15 minutes to 24 hours. OCCLUSION ALARM: Distal: The distal occlusion alarm sounds within two pumping cycles after the distal set tubing or set outlet fitting becomes occluded. Proximal: The proximal occlusion alarm sounds within five pumping cycles if the tubing proximal to the cassette becomes occluded. Air-in-Alarm: The stopped air in distal line alarm will sound if a bubble 100 uL or larger passes the distal air-in-line sensors. Alarm may actually sound at detection of a bubble as small as 50 uL) Proximal: The stopped air in proximal line alarm will sound if approximately 1200 uL or more passes trough the proximal air-in-line sensors.
Technical Specifications
| Condition | Used - Good |
| Country | France |
| Warranty (month) | 1 |
| Availability | In stock |
| Insulin infusion | Yes |
| Syringe | Yes |
| Ambulatory | Yes |
| PCA | Yes |
| Model | Lifecare 5000 |
| Brand | ABBOTT |
| Category | IV infusion pumps |
Questions & Answers
Ask a Question
ABBOTT Lifecare 5000 IV infusion pump
GOODYear 20261 ViewsBasic
3 people viewing this right now
€67.00
Get the best price — instantly
Verified sellers Avg. response 2 hrs
Typically responds in 2 hours
Inspection report available
Worldwide shipping available
Locked
Seller information hidden
Unlock to reveal name, rating & contact
Seller contact is locked
Unlock seller phone, email and full profile for a one-time fee.
Safety Tips
- • Inspect equipment before payment
- • Use MellMed secure payment
- • Verify equipment serial numbers
- • Check CE/FDA compliance docs
