
Click to zoom
GOOD
Product Details
| Brand | FRESENIUS KABI |
| Category | Infusion Pumps |
| Condition | GOOD |
| Year | 2026 |
| Ship From | 🇫🇷 |
| Posted | 9 Jul 2026 |
| Views | 11 |
FRESENIUS Kabi Volumat MC Agilia Infusion Pump Very Good condition TESTED - FUNCTIONAL Several Units Available FEATURES: Intuitive Generation of Advanced Stand Alone Infusion Pumps Flow rate range: 1-1500 ml/h in normal mode (1ml/h increment). 0.1- 99.9 ml/h in micro mode (0.1 ml/h increment). Flow rate can be limited according to drug name (soft and hard limits) with Vigilant®, the IV Medication Safety Solution. Flow rate accuracy: / -5% and even better in most clinical situations. Infusion Modes: ml/h modes: Volume Flow rate, Volume Time, Flow rate Time, Volume Time Rate, Rate only (if optional drop sensor is used), Ramp-up / Ramp-down, Sequential / Intermittent, Secondary / Piggyback, Drop/min Dose rate modes: ng/h, ng/kg/min, ng/kg/h, ng/m2/24h, μg/min, μg/h, μg/kg/min, μg/kg/h, μg/m2/min, μg/m2/h, mg/min, mg/h, mg/24h, mg/kg/min, mg/kg/h, mg/kg/24h, mg/m2/min, mg/m2/h, g/h, g/kg/min, g/kg/h, g/m2/min, g/m2/h, g/m2/24h, mU/min, mU/h, mU/kg/min, mU/kg/h, mU/m2/min, mU/m2/h, U/min, U/h, U/kg/h, U/kg/24h, U/m2/min, U/m2/h, mEq/min, Eq/h, mEq/kg/min, mEq/kg/h, mEq/m2/min, mEq/m2/h, mEq/m2/24h, mmol/h, kcal/h, kcal/24h, kcal/kg/h, kcal/kg/24h. With or without loading dose. Dose time mode: calculation of the rate is based on dose and dilution over an adjusted time. OCS patent: The Occlusivity Check System is the only auto-test to check the good working order of the pump in association with its set and thus preventing risk of free-flow. Bolus: 1500 ml/h, adjustable from 50 ml/h to 1500ml/h by 50 ml/h increments. Manual or programmable. Programming modes: No drug names: infusion without any display of the drug names. Drug labelling: infusion with the drug names displayed. Vigilant® Drug’Lib: the secured IV administration mode by soft and hard limits. Customized drug library with Vigilant®, the IV Medication Safety Solution. 2 pressure modes: variable (from 50 to 750 mmHg, 50 mmHg increment) or 3 pre-set levels. DPS: The Dynamic Pressure System - DPS - warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated. Battery: Li-Ion, battery life at least 8 hours at 100 ml/h, remaining battery life and battery charge level available on the display. Dimensions (H/W/D/) 145 x 130 x 135 mm / Weight: ~2000 gr. We ship worldwide ! Please feel free to contact us for any question! International Shipping We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days Returns If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only . Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.
Technical Specifications
| Condition | Pre-Owned - Excellent |
| Country | France |
| Warranty (month) | 1 |
| Availability | In stock |
| Insulin infusion | Yes |
| Syringe | Yes |
| Ambulatory | Yes |
| PCA | Yes |
| Model | Volumat MC Agilia |
| Brand | FRESENIUS KABI |
| Category | IV infusion pumps |
Questions & Answers
Ask a Question
FRESENIUS KABI Volumat MC Agilia IV infusion pump
GOODFranceYear 202611 ViewsBasic
13 people viewing this right now
€138.00
Get the best price — instantly
Verified sellers Avg. response 2 hrs
Typically responds in 2 hours
Inspection report available
Worldwide shipping available
Locked
Seller information hidden
Unlock to reveal name, rating & contact
Seller contact is locked
Unlock seller phone, email and full profile for a one-time fee.
Safety Tips
- • Inspect equipment before payment
- • Use MellMed secure payment
- • Verify equipment serial numbers
- • Check CE/FDA compliance docs
